Garden Nursery Products
Gold Coast · Est. 1979

Wetting Agent 20L – Wetter 600 Non-Ionic Surfactant 600g/L

Loading...
Pro-Grade Quality
24hr Dispatch
IN-STORE PICKUP ONLY · SKU: 040-001

Wetting Agent 20L – Wetter 600 Non-Ionic Surfactant 600g/L

★★★★★4.7 (55 Google reviews)·Available — In-Store Pickup Only

$132.00 Inc GST

WETTER 600 is a 20 L pack of PCT Reactor Wetter 600, a 600 g/L nonyl phenol ethylene oxide condensate surfactant for use with herbicides, insecticides and fungicides. Label rates include 10 mL per 100 L for horticultural sprays. It may irritate the eyes and skin.

Only 1 left in stock

Fast DispatchWithin 24hrs Australia-wide
Quality GuaranteedPro-grade formulations
25 kg39 × 29 × 29 cm
Need Advice?07 5537 4585
Active Ingredient600 g/L Nonyl

Related Products

Loading...

Product Description

WETTER 600 is a 20 L pack of PCT Reactor Wetter 600, a surfactant with 600 g/L nonyl phenol ethylene oxide condensate (APVMA 60788). The label says it is for use with herbicides, insecticides and fungicides, and that it increases wetting and spray coverage. It is a spray additive, not a weedkiller or pesticide on its own.

How much to add. The label gives these rates: horticultural sprays 10 mL per 100 L of spray (2 mL per 15 L knapsack); weed killing sprays 12 mL per 100 L for high volume power spray, 60 mL per 100 L for low volume boom spray and 2 mL per 15 L for knapsack; paraquat and diquat herbicides 200 mL per 100 L (30 mL per 15 L knapsack); soil residual herbicides such as diuron or atrazine 125 to 500 mL per 100 L depending on the product.

When not to add it. The label says to add it to horticultural sprays except those known to contain adequate wetting agent already, and to add it to selective herbicides only where their own label directs, because use outside label directions may reduce crop selectivity. Do not add it directly to undiluted sprays containing wetting agents. Spray only to the point where leaves are just wet: excessive use causes run-off of the active ingredient and loss of efficiency.

How to use it. It mixes easily with water and should be added directly to the spray tank. The label says it can be used with alkaline sprays. Always follow the label of the pesticide you are adding it to. The label copy we hold is the 1000 L pack label, with the directions printed for all pack sizes.

Before you buy. The label says it may irritate the eyes and skin. It asks for cotton overalls buttoned to the neck and wrist, elbow-length PVC or rubber gloves and goggles. If poisoning occurs, contact a doctor or the Poisons Information Centre on 13 11 26. Keep out of reach of children, and store in the closed original container in a cool, well ventilated area.

Delivery from $17, priced by weight and postcode at checkout.

Additional information

Weight25 kg
Dimensions39 × 29 × 29 cm
Size

20L

Safety Data Sheets (SDS)

Application Rates

General Use:

Spray Tank Mix: 10mL per 100L of water (0.01%)
Knapsack Sprayer: 2mL per 15L of water

 

For Weed Sprays:

High Volume Power Spray: 12mL per 100L of water
Low Volume Boom Spray: 60mL per 100L of water
Misting Machines: 5mL per 5L of water
Knapsack Sprayer: 2mL per 15L of water

 

For Paraquat & Diquat:

High Volume Power Spray: 200mL per 100L of water
Boom Spray: 200mL per 100L of water
Knapsack Sprayer: 30mL per 15L of water

 

For Soil Residual Herbicides:

Use between 125mL and 500mL per 100L of water, depending on the product.

 

For Fire Fighting:

Water Tanker: 10mL per 100L of water
Knapsack Sprayer: 2mL per 15L of water

 

Mixing & Spraying:

Add Reactor Wetter 600 directly to water in the spray tank—it mixes quickly and easily.
Do not add to undiluted sprays containing wetting agents.
Spray leaves until they are just wet; avoid over-spraying, as this can cause runoff and reduce effectiveness.

 

Important Notes:

These rates are a general guide.
Always read the product label, including safety and first aid instructions, before use.
Use only as directed to ensure effectiveness and safety. Misuse may be illegal and dangerous.

Tips for use

Horticultural Sprays:

Add 10mL per 100L (or 2mL per 15L knapsack) of Reactor Wetter 600 to horticultural sprays unless they already contain a wetting agent.
For waxy-leaf plants, increase the rate to improve wetting.
Spray only until leaves are just wet—avoid over-spraying to prevent run-off and loss of effectiveness.

 

Weed Sprays:

Add Reactor Wetter 600 to post-emergence herbicides unless the product label says it already includes a wetting agent.
Use as directed on individual herbicide labels to avoid crop damage.
Spray leaves and stems until just wet. Over-spraying causes chemical run-off.
For hard-to-wet plants (e.g., waxy or hairy leaves), increase the rate for better results:
High Volume Spray: 12mL/100L
Low Volume Boom Spray: 60mL/100L
Misting Machines: 5mL/5L
Knapsack: 2mL/15L

Paraquat/Diquat Herbicides (e.g., Reglone, Gramoxone):
For maximum efficiency with these herbicides, use higher rates to ensure even coverage:
High Volume Spray: 200mL/100L
Boom Spray: 200mL/100L
Knapsack: 30mL/15L
Soil Residual Herbicides:
Add Reactor Wetter 600 to thoroughly wet foliage when applying soil-active herbicides (e.g., Diuron, Atrazine):
Rates vary between 125–500mL/100L, depending on the herbicide. Check product labels.

 

Fire Fighting:

Reactor Wetter 600 improves the wetting power of water for fire control and clean-up:
Water Tanker: 10mL/100L
Knapsack: 2mL/15L

 

General Usage Instructions:

Reactor Wetter 600 is a spray additive for fungicides, insecticides, and herbicides. It enhances efficiency by improving wetting and spray coverage.
Mixes easily with all water types and is safe for tender foliage if used correctly.
Spray only until leaves are just wet to avoid waste through run-off.

 

Mixing:

Add Reactor Wetter 600 directly to the spray tank with water. Do not mix with undiluted sprays containing other wetting agents.

 

Storage:

Keep out of reach of children.
Store in a cool, ventilated area, away from direct sunlight.

 

Safety Directions:

May irritate eyes and skin. Avoid contact.
Wear protective clothing (long sleeves, gloves, goggles) when handling.
Wash skin immediately with soap and water if contact occurs.
Wash hands and face thoroughly after use.

 

First Aid:

For poisoning, call a doctor or the Poisons Information Centre (Australia: 13 11 26).
If skin contact occurs, remove contaminated clothing and wash thoroughly.
Refer to the Safety Data Sheet (SDS) for more details.

Note: Always follow product labels and seek expert advice for specific applications.

Active Ingredients

600g/L Nonyl Phenol Ethylene Oxide Condensate

Reviews

There are no reviews yet.

Be the first to review “Wetting Agent 20L – Wetter 600 Non-Ionic Surfactant 600g/L”

Your email address will not be published. Required fields are marked *

EXCLUSIVE SAVINGS

Get 5% Off WHEN YOU JOIN OUR NEWSLETTER

Get deals sent straight to your inbox